VRX dimensions |
VSX dimensions |
 |
 |
|
|
|
|
|
VRX technical datas |
| TYPE |
VRX25 |
VRX45 |
VRX75 |
| Maximal torque |
25Nm |
45Nm |
75Nm |
| Nominal torque |
20Nm |
35Nm |
60Nm |
| Voltages |
15V to 30V 50/60Hz (12V to 48V DC)
100V to 240V 50/60Hz (100V to 350V DC)
400V three phase |
| Operating time for 90° (±1s) |
7s (15s*) / 400V : 10s |
15s / 400V : 10s |
20s / 400V : 15s |
| Power |
45W / 400V : 52W |
45W/ 400V : 52W |
45W/ 400V : 52W |
| Star drive nut |
17mm |
| ISO connection |
F05/F07 |
| Limit switches |
4 (2 adjustables) |
| Rotation angle |
90° (0°-180° or 0°-270° on request) |
| Duty rating |
50% |
| Protection |
IP67
ATEX : II 2 GD Ex d IIB T6 - tD A21 IP67 T80°C
(FAILSAFE and 400V = T5 and 95°C) |
| Temperature |
-10°C to +55°C (FAILSAFE : -10 to 40°C) |
| Weight |
4 Kg to 4.4 Kg |
| * Operating time in 4-20 mA mode (POSI) |
|
|
|
|
|
VSX technical datas |
| TYPE |
VSX100 |
VSX150 |
VSX300 |
| Maximal torque |
100Nm |
150Nm |
300Nm |
| Nominal torque |
75Nm |
125Nm |
250Nm |
| Voltages |
15V to 30V 50/60Hz (12V to 48V DC)
100V to 240V 50/60Hz (100V to 350V DC)
400V three phase |
| Operating time for 90° (±1s) |
15s / 400V : 10s |
30s / 400V : 20s |
60s / 400V : 35s |
| Power |
45W / 400V : 135W |
45W/ 400V : 135W |
45W/ 400V : 135W |
| Star drive nut |
22mm |
| ISO connection |
F07/F10 |
| Limit switches |
4 (2 adjustables) |
| Rotation angle |
90° (0°-180° or 0°-270° on request) |
| Duty rating |
50% |
| Protection |
IP67
ATEX : II 2 GD Ex d IIB T6 - tD A21 IP67 T80°C
(FAILSAFE and 400V = T5 and 95°C) |
| Temperature |
-10°C to +55°C (FAILSAFE : -10 to 40°C) |
| Weight |
6 Kg to 6.4 Kg |