ATEX

Description

ATEX electric actuator, aluminium housing with manual override by external shaft or hand wheel for torques of 25 to 2400 Nm and in accordance with CE-ROHS-REACH directives.

Versions

Technical Data

VRX/VSX

  • Multivoltage actuator
    • 100 V to 240 V 50/60 Hz (100 V to 350 V DC)
    • 15 V to 30 V 50/60 Hz (12 V to 48 V DC)
    • 3-phase 400V 50/60Hz
  • On-off or 3 modulating point control
  • 2 adjustable limit switches 5A for position feedback
  • connection according ISO5211:
    • VRX: F05/F07 star 17 mm
    • VSX: F07/F10 star 22 mm
  • Manual override
  • Torque limiter monitored by software (except 400 V)
  • Failure report relay (except 400 V)
  • RS485 connection (except 400 V)
  • Mechanical end stops
  • Visual position indicator
  • Regulated anticondensation heater
  • Duty rating S4 50% (CEI34)
  • Enclosure IP68 5 m / 72 h (option 10 m / 72 h for VSX)
  • Weight :  4.4 kg to 7.5 kg

VTX

  • 3-phase 400V 50Hz
  • 2 adjustable limit switches 5A for position feedback
  • connection according ISO5211:  F10/F12 star 36 mm
  • Manual override
  • Mechanical torque limiter
  • Failure report relay
  • Mechanical end stops
  • Visual position indicator
  • Regulated anticondensation heater
  • Duty rating S4 50% (CEI34)
  • Enclosure IP68 5 m / 72 h
  • Weight :  25 kg

VTX PLUS

  • Multivoltage actuator
    • 100 V to 240 V 50/60 Hz (100 V to 300 V DC)
    • 24 V to 48 V 50/60 Hz (24 V to 72 V DC)
  • On-off or 3 modulating point control
  • 2 adjustable limit switches 5A for position feedback
  • connection according ISO5211:
    • 400 / 600 / 1000 Nm : F10/F12 star 36 mm
    • 1500 / 2400 Nm : F12/F14/F16 star 46 mm
  • Manual override
  • Torque limiter monitored by software
  • Failure report relay
  • RS485 connection
  • Bluetooth® wireless connection
  • Mechanical end stops
  • Visual position indicator
  • Regulated anticondensation heater
  • Duty rating S4 50% (CEI34)
  • Enclosure IP68 5 m / 72 h (option 10 m / 72 h)
  • Weight : 25 kg (400-1000 Nm) and 57 kg (1500-2400 Nm)

VRX

vrx-150

VSX

vsx-150

VTX

vtx-150

VTX PLUS
400-1000 Nm

vtx-plus-400-1000-600x600

VTX PLUS
1500-2400 Nm

tmb-valpes-vtx-plus-2400-3d
Code ATEX Marking Operating ambient temperature N° LCIE
(ATEX)
N° LCIE
(IECeX)
N° UKCA
Category Gas Dusts
VRX/VSX (standard) II 2 G D Ex db IIB T6 Gb Ex tb IIIC T80°C Db -20 °C to +70 °C 06 ATEX 6006 X 21.0015X ITS21UKEX0157X
VRX/VSX (with battery) II 2 G D Ex db IIB T6 Gb Ex tb IIIC T80°C Db -10 °C to +40 °C
VRX/VSX (400 V) II 2 G D Ex db IIB T5 Gb Ex tb IIIC T95°C Db -20 °C to +54 °C
VTX II 2 G D Ex db IIB T5 Gb Ex tb IIIC T90°C Db -20 °C to +63 °C 15 ATEX 3012 X 15.0074X
VTX PLUS (standard) II 2 G D Ex db h IIC T5 Gb Ex h tb IIIC T91°C Db -20 °C to +70 °C 25 ATEX 3008 X
VTX PLUS (with battery) II 2 G D Ex db h IIC T6 Gb Ex h tb IIIC T66°C Db -10 °C to +40 °C

The 2014/34/UE European directive specifies the conditions for the devices to be installed in explosives atmosphere.
Our explosion-proof actuators comply with ATEX and CEM directives (all certificates are available on this website).
VRX • VSX VTX
Denomination Covered areas Covered areas
Installation places II II Approved equipment for surface industries
Protection level 2 2 &3 2 2 &3 Installation into chemical, petrochemical, agriculture, food industry…
Zones d’implantation pour les gaz, vapeurs, liquides G Zone 1
Zone 2
G Zone 1
Zone 2
Zone 1: presence of explosive substances (gas) between 10 and 1000 hours/year
Zone 2: presence of explosive substances (gas) less than 10 hours/year
Zones d’implantation pour les gaz D Zone 21
Zone 22
D Zone 21
Zone 22
Zone 21: presence of explosive substances (dusts) between 10 and 1000 hours/year
Zone 22: presence of explosive substances (dusts) less than 10 hours/year
IEC marking Ex   Ex   GAS
Type of protection (gas) db   db   Flameproof enclosure protection
Gases in the atmosphere IIB IIB & IIA & I IIB IIB & IIA & I ethylene, propane, methane
Maximum surface temperature (gas) T6
T6 (85°C)
T5 (100°C)
T4 (135°C)
T3 (200°C)
T2 (300°C)
T1 (450°C)
T5
T5 (100°C)
T4 (135°C)
T3 (200°C)
T2 (300°C)
T1 (450°C)
Maximum authorized temperature of the housing for equipment installation (gas)
Equipment Protection Levels Gb Zone 1
Zone 2
Gb Zone 1
Zone 2
Possible installation in zones 1 & 2
IEC marking Ex   Ex   DUSTS
Type of protection (dusts) tb   tb   Flameproof enclosure protection
Dusts in the atmosphere IIIC IIIC
IIIB
IIIA
IIIC IIIC
IIIB
IIIA

IIIC: conductive dusts
IIIB: non conductive dusts
IIIA: flammable fiber lints
Température maximale de surface (poussières) T80°C T90°C Maximum authorized temperature of the housing for equipment installation (dusts)
Equipment Protection Levels Db Zone 21
Zone 22
Db Zone 21
Zone 22
Possible installation in zones 21 & 22

 

Multivolt VRX and VSX models
Code Star drive nut Connection Torque Voltage supplies Power Operating time
VRX25.70A.G00 17 F05/F07 25Nm 100V to 240V 50/60Hz (100V to 350V DC) 45W 7s
VRX25.70B.G00 17 F05/F07 25Nm 15V to 30V 50/60Hz (12V to 48V DC) 45W 7s
VRX45.70A.G00 17 F05/F07 45Nm 100V to 240V 50/60Hz (100V to 350V DC) 45W 15s
VRX45.70B.G00 17 F05/F07 45Nm 15V to 30V 50/60Hz (12V to 48V DC) 45W 15s
VRX75.70A.G00 17 F05/F07 75Nm 100V to 240V 50/60Hz (100V to 350V DC) 45W 20s
VRX75.70B.G00 17 F05/F07 75Nm 15V to 30V 50/60Hz (12V to 48V DC) 45W 20s
VSX100.90A.G00 22 F07/F10 100Nm 100V to 240V 50/60Hz (100V to 350V DC) 45W 15s
VSX100.90B.G00 22 F07/F10 100Nm 15V to 30V 50/60Hz (12V to 48V DC) 45W 15s
VSX150.90A.G00 22 F07/F10 150Nm 100V to 240V 50/60Hz (100V to 350V DC) 45W 30s
VSX150.90B.G00 22 F07/F10 150Nm 15V to 30V 50/60Hz (12V to 48V DC) 45W 30s
VSX300.90A.G00 22 F07/F10 300Nm 100V to 240V 50/60Hz (100V to 350V DC) 45W 60s
VSX300.90B.G00 22 F07/F10 300Nm 15V to 30V 50/60Hz (12V to 48V DC) 45W 60s
3-phase 400V VRX et VSX models
Code Star drive nut Connection Torque Voltage supplies Power Operating time
VRX25.709.R00 17 F05/F07 25Nm 400V 3-phase 50/60Hz 52W 10s
VRX45.709.R00 17 F05/F07 45Nm 400V 3-phase 50/60Hz 52W 10s
VRX75.709.R00 17 F05/F07 75Nm 400V 3-phase 50/60Hz 52W 15s
VSX100.909.R00 22 F07/F10 100Nm 400V 3-phase 50/60Hz 135W 10s
VSX150.909.R00 22 F07/F10 150Nm 400V 3-phase 50/60Hz 135W 20s
VSX300.909.R00 22 F07/F10 300Nm 400V 3-phase 50/60Hz 135W 35s
3-phase 400V VTX models
Code Star drive nut Connection Torque Voltage supplies Power Operating time
VTX600.A09.R00 36 F10/F12 600Nm 400V 3-phase 50Hz 250W 38s
VTX1000.A09.R00 36 F10/F12 1000Nm 400V 3-phase 50Hz 250W 38s
VTX+ models
Code Star drive nut Connection Torque Voltage supplies Power Operating time
VTX400.A0A.G00 36 F10/F12 400Nm 100V to 240V 50/60Hz (100V to 300V DC) 300W 35s
VTX400.A0B.G00 36 F10/F12 400Nm 24V to 48V 50/60Hz (24V to 72V DC) 300W 35s
VTX600.A0A.G00 36 F10/F12 600Nm 100V to 240V 50/60Hz (100V to 300V DC) 300W 45s
VTX600.A0B.G00 36 F10/F12 600Nm 24V to 48V 50/60Hz (24V to 72V DC) 300W 45s
VTX1000.A0A.G00 36 F10/F12 1000Nm 100V to 240V 50/60Hz (100V to 300V DC) 300W 72s
VTX1000.A0B.G00 36 F10/F12 1000Nm 24V to 48V 50/60Hz (24V to 72V DC) 300W 72s
VTX1500.B0A.G00 46 F14 1500Nm 100V to 240V 50/60Hz (100V to 300V DC) 300W 182s
VTX1500.B0B.G00 46 F14 1500Nm 24V to 48V 50/60Hz (24V to 72V DC) 300W 182s
VTX1500.C0A.G00 46 F12/F16 1500Nm 100V to 240V 50/60Hz (100V to 300V DC) 300W 182s
VTX1500.C0B.G00 46 F12/F16 1500Nm 24V to 48V 50/60Hz (24V to 72V DC) 300W 182s
VTX2400.B0A.G00 46 F14 2400Nm 100V to 240V 50/60Hz (100V to 300V DC) 300W 291s
VTX2400.B0B.G00 46 F14 2400Nm 24V to 48V 50/60Hz (24V to 72V DC) 300W 291s
VTX2400.C0A.G00 46 F12/F16 2400Nm 100V to 240V 50/60Hz (100V to 300V DC) 300W 291s
VTX2400.C0B.G00 46 F12/F16 2400Nm 24V to 48V 50/60Hz (24V to 72V DC) 300W 291s
Options
EPR…B 1) 100 / 1000 / 5000 / 10000 Ohms feedback potentiometer
EPT.C 2) 0-20mA / 4-20mA / 0-10V transmitter
EFC.2 Card with 2 Extra limit switches
IP10 3) 10 meters 72 hours IP68 tightness (VSX only)
MARINE High durability marine coating
HUMPRO Mainboard conformal coating
P8 AXMART® Bluetooth® 4-20mA or 0-10V positioning board, compatible with Modbus-RTU
1) Specify the model
2) Only for a travel time higher or equal to 10s
3) Delivered without cable gland